The criteria for acceptance and rejection of TB specimens at TB Diagnostic Laboratories are listed below:
Acceptance Criteria:
- Sample received in triple layer with no leakage
- Sample is without any blood and food particles
- Sample is received within 48 hours expected timeline after collection in a cool chain
- Adequate label and information about the specimen
- Identical name on the specimen and in the test request
- Sample is in adequate quantity
Rejection Criteria:
- Unlabeled or mislabeled specimens
- Specimen sent without the test request ID in Nikshay
- Mismatch in the name on the specimen and the test request in Nikshay
- If the container is full up to the lid with the specimen
- Sample is not collected in an appropriate container
- Specimen container is broken
- Leakage of specimen
- Sample received after two days of collection